Single Phase Portable Meter Test System MCCS1.1
Accuracy class of direct mode | 0.1 |
Accuracy class (clamp 10A, 50A, 100A, 300A…optional) | 0.2 |
Technical index of in-built single phase standard meter | |
Class | 0.1 |
Input current range | 0.025A, 0.05A, 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 20A, 50A, 100A |
Input voltage range | up to 300V |
Display resolution | 6 digits (valid) |
Output voltage | up to 240V, 120% adjustable (maximum up to 288V) |
Adjust resolution | better than 0.01% |
Output current range | 0.05A, 0.25A, 1A, 5A, 20A, 100A |
0-120% adjustable; | |
Adjust resolution | better than 0.01% |
Minimum output current | 1mA (≤5%) |
Output power | 30VA for current and 50VA for voltage (only test one meter) |
100VA for current and 50VA for voltage (test three meters at the same time) | |
Output stability of voltage, current and power | ≤0.05% /120s |
Waveform distortion of output voltage/current | ≤0.5% |
Frequency range | 45-65HZ |
Adjust resolution | 0.01Hz |
Phase angle range | -180.0o ~180.0o |
Adjust resolution | 0.01° |
Power supply | AC 220V±10%,50/60HZ; or from measuring circuit |
Power consumption | 200VA (maximum) |
Dimension & Weight | 361*236*163mm & 7kg (main unit) |