Products

  • Inductive Voltage Divider HJF1

    Inductive Voltage Divider HJF1

    Portable Type, easy to carry.

    Can work as one part of CT PT test system.

    Can be used as other purpose.

    Accuracy class: 0.005.

  • Multi function Partial Discharger Tester MCPD004

    Multi function Partial Discharger Tester MCPD004

    7”LCD display, touch screen, ARM processor and inbuilt operation system, friendly HMI.

    Can be operated by android system terminal,Adopting android system and providing special-use test software.

    Partial discharge test and location of GIS, Switchgear, Cable tray, cable joint, insulators & LBS on transmission line, transformer, cables and etc.

    Test result can show discharge strength, discharge phase, history data, etc.

  • Standard Potential Transformer (6-35KV)

    Standard Potential Transformer (6-35KV)

    High accuracy and stability Use as a standard PT for PT testing 0.05 class or 0.02 or higher (optional) Small excitation current Integrated with voltage generator are available.

  • Sweep Frequency Response Analyzer SFRA20

    Sweep Frequency Response Analyzer SFRA20

    Adopting frequency-sweep method to measure transformer winding characteristics.

    Deformations of windings such as distortion, swell or displacement of transformer measured by detecting amplitude-frequency response characteristics of each winding, not requiring lifting of transformer enclosure or disintegration.

    Quick measuring, measuring of a single winding is within 2 minutes.

    High frequency accuracy, higher than 0.001%.

  • Inductive Voltage Divider FJG

    Inductive Voltage Divider FJG

    Portable Type, easy to carry

    Can work as one part of CT PT test system

    Can be used as other purpose

    Accuracy class: 0.001

  • Portable Partial Discharge (PD) Tester MCPD001

    Portable Partial Discharge (PD) Tester MCPD001

    Can detect PD activities in bother ultrasonic and TEV mode.

    LCD backlit display.

    Can test switchgear, overhead cables including transmission line, and etc.

    Protection: IP54.

    Chargeable batteries power supply.

    TEV measuring range 0-60dBmV; Ultrasonic measuring range -7 to 68dB μV.

  • Double Stage Standard PT with voltage Generator HJS6-10-35

    Double Stage Standard PT with voltage Generator HJS6-10-35

    high accuracy and high voltage level.

    Can test 0.2 class or higher voltage transformer with 35kV,35/√3kV,10kV,10/√3kV,0.2VA secondary burden (at 100V); 0.07VA secondary burden (at 100/√3V)

    Double stage with voltage generator Stable and reliable output

  • MCOT100 Oil Dielectric Loss Test Set

    MCOT100 Oil Dielectric Loss Test Set

    Test cell adopt three-electrode-type structurZ Adopting medium frequency induction heating.

    Large LCD display Measure range: 5pF-200pF (electric capacity); 1.000-30.000 (relative permittivity); 0.00001 – 100 (dielectric loss factor); 2.5 MΩm~20 TΩm (Resistivity).

    Temperature setting range: 0~125℃.

    AC voltage setting range: 500~2200V.

    DC voltage setting range 0~500V.

  • HES Series Transformer Tester

    HES Series Transformer Tester

    LCD display.

    Ratio error and phase angle error test.

    Impedance and admittance test.

    With PC software.

  • Portable Primary Injection Test Set MCTG300C

    Portable Primary Injection Test Set MCTG300C

    Single phase current outputs up to 1000A.

    Output can be AC or DC.

    Inject current from primary side to check polarity and test whole protection.

    Current outputs fully programmable.

  • High Voltage Standard Potential Transformer HJ series (66-500KV)

    High Voltage Standard Potential Transformer HJ series (66-500KV)

    1) 110-500KV/√3kV maximum range for option.

    2) High accuracy and stability and performance.

    3) Used as a standard for PT testing.

    4) Different design for different maximum voltage level.

    Customized according to client requirement is available.

  • Three Phase Meter Test Bench

    Three Phase Meter Test Bench

    1. Error test, start test, creep test, standard deviation test..etc

    2. Measurement of volts, current, p.f., power, frequency, phase angle, harmonic..etc..

    3. Power Source (PS): output 0-360V/phase & 1mA-120A/phase, or depend on client requirement

    4. Standard Reference Meter (SRM): accuracy class (0.02, 0.05 or 0.1) is optional

    5. Can be independent set & output of each phase voltage & current

    6. Can set phase angle independently

    7. Meter Rack: positions (3, 6, 10, 12, 20, 24,40..) are optional

    8. Automatic control by PC software

    9. Manual control by touch screen