Products

  • Resonant High Voltage Source System

    Resonant High Voltage Source System

    Can work together with High Voltage Standard PT

    Big rated capacity and stable output

    With Over current & over voltage protection function

    Fine & coarse adjustment

  • ZYD-100 Transformer Oil Two-stage Vacuum Oil Filter

    ZYD-100 Transformer Oil Two-stage Vacuum Oil Filter

    Rapidly and totally decompose moisture from emulsified oil, avoid emulsifying repeatedly.

    Separate moisture, gas rapidly with high dewatering and high degas efficiency. After filtering, Water-content ≤5PPm,gas-content ≤0.01%.

    PLC control system.

  • Double Stage Standard Current Transformer BL258H

    Double Stage Standard Current Transformer BL258H

    High accuracy, can be up to class 0.002.

    5 to 5000A current transformer design (or according to client requirement).

    Used for precision measurement of calibration of instrument CT.

    Integrated with current source (optional).

    Double stage burden ±2.5±j2.5mΩ.

  • Portable Three Phase Meter Test System MCPTS4.0

    Portable Three Phase Meter Test System MCPTS4.0

    1.Error test, start test, creep test, dial test, CT ratio error test, CT phase angle error test, CT/PT burden test

     

    2.Can be independent set & output of each phase voltage & current

     

    3.Can be independently used as portable reference meter

     

    4.External connect with thermal printer (optional)

     

    5.Can operate by PC software

     

    6.Manual control by touch screen/keypad

  • Portable Three Phase Reference Standard Meter MCSB03B

    Portable Three Phase Reference Standard Meter MCSB03B

    Small size and weight.

    Used in lab or worksite.

    Work as standard meter and calibrator in worksite or lab.

    LCD display.

    Accuracy class: 0.05 or 0.02 (optional).

    Measuring range: 3*(1V-576V)/3*(1mA-120A).

    Power and Energy test, Demand test, CT burden & Ratio Test, PT load test, Dial test.

    Optional for DC measurement for transducer test.

  • Inductive Voltage Divider HJF1

    Inductive Voltage Divider HJF1

    Portable Type, easy to carry.

    Can work as one part of CT PT test system.

    Can be used as other purpose.

    Accuracy class: 0.005.

  • Multi function Partial Discharger Tester MCPD004

    Multi function Partial Discharger Tester MCPD004

    7”LCD display, touch screen, ARM processor and inbuilt operation system, friendly HMI.

    Can be operated by android system terminal,Adopting android system and providing special-use test software.

    Partial discharge test and location of GIS, Switchgear, Cable tray, cable joint, insulators & LBS on transmission line, transformer, cables and etc.

    Test result can show discharge strength, discharge phase, history data, etc.

  • Standard Potential Transformer (6-35KV)

    Standard Potential Transformer (6-35KV)

    High accuracy and stability Use as a standard PT for PT testing 0.05 class or 0.02 or higher (optional) Small excitation current Integrated with voltage generator are available.

  • Sweep Frequency Response Analyzer SFRA20

    Sweep Frequency Response Analyzer SFRA20

    Adopting frequency-sweep method to measure transformer winding characteristics.

    Deformations of windings such as distortion, swell or displacement of transformer measured by detecting amplitude-frequency response characteristics of each winding, not requiring lifting of transformer enclosure or disintegration.

    Quick measuring, measuring of a single winding is within 2 minutes.

    High frequency accuracy, higher than 0.001%.

  • Inductive Voltage Divider FJG

    Inductive Voltage Divider FJG

    Portable Type, easy to carry

    Can work as one part of CT PT test system

    Can be used as other purpose

    Accuracy class: 0.001

  • Portable Partial Discharge (PD) Tester MCPD001

    Portable Partial Discharge (PD) Tester MCPD001

    Can detect PD activities in bother ultrasonic and TEV mode.

    LCD backlit display.

    Can test switchgear, overhead cables including transmission line, and etc.

    Protection: IP54.

    Chargeable batteries power supply.

    TEV measuring range 0-60dBmV; Ultrasonic measuring range -7 to 68dB μV.

  • Double Stage Standard PT with voltage Generator HJS6-10-35

    Double Stage Standard PT with voltage Generator HJS6-10-35

    high accuracy and high voltage level.

    Can test 0.2 class or higher voltage transformer with 35kV,35/√3kV,10kV,10/√3kV,0.2VA secondary burden (at 100V); 0.07VA secondary burden (at 100/√3V)

    Double stage with voltage generator Stable and reliable output