Portable Three Phase Power Source UTI

Can be externally controlled by computer through RS232 setting the parameters on computer and then test by control software; can be used independently also can be used together with reference standard meter.

Also can be operate by the keyboard on the faceplate

With LED indicator on the face plate after power on the unit

With voltage measurement facility and loop back control.

With measurement mode selection, namely 3P3W, 3P4W and 1P2W.  When select 3P3W, automatically deactivate L2 phase current and when select 1P2W, automatically deselect L2 and L3 phases.

With overload, short circuit and thermal overload protection.

When accuracy of the unit changes, can calibrate it by given method by yourself.

With package avoiding damage and disturbance.

Single phase power supply, range 85-282V,  47 to 63Hz.

Working conditions: -10℃ to 50℃, 10%-95% R.humidity.


Features

Technical Index

Can be externally controlled by computer through RS232 setting the parameters on computer and then test by control software; can be used independently also can be used together with reference standard meter.

Also can be operate by the keyboard on the faceplate.

With LED indicator on the face plate after power on the unit.

With voltage measurement facility and loop back control.

With measurement mode selection, namely 3P3W, 3P4W and 1P2W.  When select 3P3W, automatically deactivate L2 phase current and when select 1P2W, automatically deselect L2 and L3 phases.

With overload, short circuit and thermal overload protection.

When accuracy of the unit changes, can calibrate it by given method by yourself.

With package avoiding damage and disturbance.

Single phase power supply, range 85-282V,  47 to 63Hz.

Working conditions: -10℃ to 50℃, 10%-95% R.humidity.

Display below parameters (7” LCD).

True RMS value of voltage for each phase.

True RMS value of phase to phase voltage.

Harmonics distortion in each phase and total harmonic distortion.

Phase current.

Phase angle between voltages.

Phase angle between voltage and current.

Active, reactive and apparent power of each phase.

Total power factor.

Total active, reactive and apparent power.

Instantaneous power factor for each phase.

Frequency.

Vector diagram.

Accessories.

Current & Voltage cable.

Power cord.

User manual.

Package box and other necessary accessories to complete the job.


  • Previous:
  • Next:

  • Model No. UTI-10 UTI-100
    Description 1mA-12A, accuracy class 0.05 or  0.1 1mA-120A, accuracy class 0.05 or 0.1
    Supply Voltage AC 85-282V, 47-63HZ AC 85-282V, 47-63HZ
    Power Consumption 290VA 450VA
    Influence of auxiliary voltage ≤0.005% at 10% variation ≤0.005% at 10% variation
    Dimension 510*600*170mm 510*600*170mm
    Weight 20KG 27KG
    Frequency Range 45-69HZ 45-69HZ
    Frequency Resolution 0.001HZ 0.001HZ
    Frequency Error Less than 0.01HZ Less than 0.01HZ
    Phase Angle Range 0-359.99° 0-359.99°
    Phase Angle Resolution 0.001° 0.001°
    Phase Angle Error 0.1° 0.05°
    Communication Port RS232 RS232
    Range (P-N) 30-300V 30-300V
    Power 3*25VA 3*30VA
    Display Resolution Six significant digits Six significant digits
    Output accuracy 0.1% 0.05%
    Output stability Better than 0.05%/2min Better than 0.05%/2min
    Distortion Better than 0.5% Better than 0.5%
    Range 1mA-12A 1mA-120A
    Power 3*25VA 3*30VA
    Display Resolution Six significant digits Six significant digits
    Output accuracy 0.1% 0.05%
    Output stability Better than 0.05%/2min Better than 0.05%/2min
    Distortion Better than 0.5% Better than 0.5%
    Fundamental Frequency range 45-69HZ 45-69HZ
    Range 2-31st times 2-31st times
    Maximum content in both voltage and current circuit 40% 40%
    Active power 0.1% 0.05%
    Reactive power 0.2% 0.1%
    Apparent power 0.1% 0.05%
    Power factor 0.1% 0.05%
    Voltage 0.1% 0.05%
    Current 0.1% 0.05%
    Phase 0.1° 0.05°
  • Write your message here and send it to us